ERG HomeProductsOEM Cross ReferenceTechnical ResourceAbout ERGContact Us

The JLA Series
Overview (Standard and P Package Inverters)

Parameter Symbol Units Code
D
Code
1
Code
2
Code
3
Input Power per Unit Load

Pin

watts

*0.150 *0.200 *0.300 *0.400
Minimum Input Voltage

Vin(min)

%

-40 -40 -40 -40
Maximum Input Voltage

Vin(max)

%

25 25 25 25
Minimum Operating Temperature T(min) C -25 -25 -25 -25
Maximum Operating Temperature T(max) C 85 85 85 85
Nominal Output Voltage Vout Vrms 60 80 100 120
Nominal Operating Frequency Fout Hz 400 400 400 400
Maximum Number of Unit Loads Lmax -- 20 13 9 8
Output Voltage Tolerance - % +10 +10 +10 +10
Operating Frequency Tolerance - % +10 +10 +10 +10
Output Current per Unit Load Iout marms 1.7 2.3 2.9 3.5

* Input power may increase by 10% on low input voltage and/or single unit load inverters

The JLA Series Unit Load

Each Unit Load

C = .011 uf

R = 125 Kohms

 

 

 

 
 

 

Endicott Research Group, Inc. • 2601 Wayne Street • Endicott, NY 13760
Phone: 800.215.5866 • Phone: 607.754.9187 • Fax: 607.754.9255sales@ergpower.com

ISO
  UL

Copyright© 2009